For 24 floors, you can choose any command type as up/down mix. collective, down collective, up collective, selective collective.
Call buttons and call lamps need only one shared wire.
Last 16 faults including datum of floor, direction, day and hour can be traced on LCD screen.
Overload function.
You can choose extra outputs as binary / gray-code or gong outputs. These outputs can drive all LCD screens on external installation.
Outputs for direction arrows, Out Of Service signal and busy signal via 5 A relay, signal common input for these outputs.
Full load function.
Attendant contact.
Function of moving to the adjustable fre floor on fre.
Adjustable park floor and duration of parking time.
Up and down pulse bi-stable switches inputs for position information and shaf learning with encoder.
Adjustable car lamp time, lock wait time, wait at floor time, max high speed time and max low speed time.
Adjustable maintenance time, warning when it is the maintenance time on LCD screen.
In stand-by mode the runtime of the lif afer the last maintenance (as day and hour) is screened on LCD screen.
Electronic controlling of phases, phase order and PTC (Motor temperature), shown faults about these controls via LCD screen, turn off the functions by choosing the parameters, adjustable phase level sensitive.
Internal automatic door card, adjustable times for working of automatic doors, chosing door type for each floors and adjustable door which will open reguested floor (both can be opened on the same floor).
By adding MLSERI65 card, full support to double automatic door without additional card.
Chosing this door open signal type of working related to direction arrows.
It can be used for dublex lifs by communicated with only two wires.
In hydraulic lifs, by adding MLKR1 card, it can be done re-levelling when the door is open.
By adding MLKR1 card, it can be done advance door opening.
By using MLSERI65 card, it can be CANBUS communicated with car, so saving in time, cable and labour costs.
Chosing top missing floor and upper missing floor in doublex usage.
Parameter support for rescue with UPS 10 A normal open contact (RX) that is pogrammed re-levelling delay time with parameter in motor driving systems.
Necessary inputs and outputs for rescue operation at system with gearless synchrnous motor.
Programmable inputs and outputs.
Cancellation the tracking of OSG contact or brake feed back
For 16 floors, you can choose as universal or up/down mix. collective.
Call buttons and call lamps need only one shared wire.
Programming with password protection, PUK code protection against unauthorized using.
It can be traced last 16 faults, floors, directions with day and hour informations on LCD.
At waiting position, it can be traced how long (day, hour) is the lif worked afer last maintenance on LCD.
Adjustable maintenance time, warning on LCD when the maintenance time off.
Overload input warning signal.
Short-circuit protected display outputs can be adjusted to every floor.
Changing the display outputs to graycode or binary outputs.
Outputs for direction arrows, Out Of Service signal and busy signal via 5A relay, signal common input for these outputs.
Adjustable park floor and duration of parking time. Pulse bi-stable switches for position information.
Adjustable car lamp time, lock wait time, wait at floor time, max high speed time and max low speed time.
Door open signal (AUTO) and chosing this signal type of working related to direction arrows.
For the lifs which has only one door is full automatic, chosing the floor where the full tautomatic door is.
Electronic controlling of phases, phase order and PTC (Motor temperature), shown faults about these controls via LCD on board, turn off the functions by choosing the parameters, adjustable phase level sensitive